Problem
This technical bulletin applies to GroundWork Monitor 7.2.0. On GroundWork systems failure occurs when importing RRD data that occurs before the cutoff date. This fix now displays a correct error message and always rejects RRD input when it matches current influxDB data.
Solution
To address the problem above, we are providing an updated grafbridge-control script file.
Installation steps
- Download the TB7.2.0-3.tar.gz tarball below and place in an accessible location on your GroundWork Server.
- Unzip the tarball:
tar zxvf TB7.2.0-3.tar.gz
This will create the sub-directory TB7.2.0-3.
- Change to the TB7.2.0-3 directory:
cd TB7.2.0-3
- As root user run install:
./TB7.2.0-3_install.sh
Uninstall rollback steps
- As root user, in the Technical Bulletin directory (e.g., TB7.2.0-3) run uninstall:
./TB7.2.0-3_uninstall.sh