GWME-7.2.0-3 Importing RRDs

Problem

This technical bulletin applies to GroundWork Monitor 7.2.0. On GroundWork systems failure occurs when importing RRD data that occurs before the cutoff date. This fix now displays a correct error message and always rejects RRD input when it matches current influxDB data.

Solution

To address the problem above, we are providing an updated grafbridge-control script file.

Installation steps
  1. Download the TB7.2.0-3.tar.gz tarball below and place in an accessible location on your GroundWork Server.
    Name Size Creator Creation Date Comment  
    TB7.2.0-3.tar.gz 37 kB Bren Eckles Jun 01, 2018 19:51    
  2. Unzip the tarball:
    tar zxvf TB7.2.0-3.tar.gz
    

    This will create the sub-directory TB7.2.0-3.

  3. Change to the TB7.2.0-3 directory:
    cd TB7.2.0-3
    
  4. As root user run install:
    ./TB7.2.0-3_install.sh
    
Uninstall rollback steps
  1. As root user, in the Technical Bulletin directory (e.g., TB7.2.0-3) run uninstall:
    ./TB7.2.0-3_uninstall.sh
    